Skip to main content

Table 2 Experimental result of detection rate

From: Accuracy to detection timing for assisting repetitive facilitation exercise system using MRCP and SVM

Subject name Detection rate for shift time r  %
70 ms 140 ms 210 ms 280 ms 350 ms
Average all subjects 70.9 72.0 71.8 72.9 72.5
Subject A 69.0 68.0 69.0 67.5 73.5
Subject B 65.6 69.9 69.4 69.4 65.1
Subject C 78.2 78.2 77.1 81.9 79.3